Since 2004, HUDA has been focusing on innovation in environmental test machine, battery test machine, rubber and plastic testing machines, UTM, etc., with rich experiences and a proactive attitude.
Lab test machines manufacturers & suppliers
Battery Short Circuit Test Chamber丨UN38.3 IEC62133 UL 1642
Categories | Battery Test Machine |
---|---|
Brand | HUDA Test Machine Manufacturer |
Model | HUD-H201-S |
Inner dimensions | 400x400x400mm |
Outside dimensions | 800x700x1310mm |
Temperature range | RT+10~200℃ |
Temperature display accuracy | 0.1℃ |
Temperature stability | ±1.0℃ |
Temperature uniformity | ±2℃ |
FOB port | shenzhen |
Terms of Payment | L/C, D/A, D/P, T/T, Paypal |
Update Time | Oct 6,2024 |
Battery Short Circuit Test Machine is used to test whether the battery will explode and catch fire when a certain resistance is short-circuited under high temperature, and at the same time display the maximum short-circuit current through the relevant instrument.
Test Standard
- UN38.3 "United Nations Manual of Tests and Standards for Transport of Dangerous Goods"
- IEC62133"Battery (group) composed of batteries and safety requirements for portable equipment"
- UL 1642:2012 "Lithium Battery Standard"
- GB/T 31485-2015 "Safety requirements and test methods for power batteries for electric vehicles"
- GB/T 31241-2014 "Safety requirements for lithium-ion batteries and battery packs for portable electronic products"
1. Inner size | 400x400x400mm (width x depth x height); |
2. Dimensions | 800x700x1310mm (width x depth x height); |
3. Temperature range | RT+10~200℃; |
4. Temperature display accuracy | 0.1℃; |
5. Temperature stability | ±1.0℃; |
6. Temperature uniformity | ±2℃; |
7. Heating time | (5±1)℃/min; |
8. Internal material | SUS304 stainless steel plate, thickness 1.2mm; |
9. External material | 1.5mm thick cold-rolled steel plate with paint treatment; |
10. Box door | a single door opens to the left, and an explosion-proof chain is installed on the side of the box door; |
11. Smoke exhaust pipe | diameter φ100mm, located at the back of the box |
12. Control method | |
13. Temperature collection range | RT+10 ~ 1000℃; |
14. Temperature acquisition channel | 1 channel; |
15. Voltage acquisition range | 0-100V; |
16. Voltage acquisition channel | 1 channel; |
17. Maximum short-circuit current | 1000A; |
18. Current acquisition channel | 1 channel; |
19. The internal resistance of the device loop | 80±20mΩ; |
20. Pressure relief door size | 200x200mm; |
Place the fully charged battery in an environment of 55°C±5°C. After the surface temperature of the battery reaches 55°C±5°C, leave it for 30 minutes, then connect the positive and negative terminals of the battery with wires, and ensure that all external resistances are at 80°C. ±20mΩ, monitor the battery surface temperature change during the test. When one of the following two situations occurs, the test is terminated:
(1) The battery surface temperature drops 20% lower than the peak value;
(2) The short circuit time reaches 24 hours;
The battery should not fire or explode, and the maximum temperature should not exceed 150°C.
- 1
Meet multiple standards
- 2
PLC touch screen control
- 3
Glass observation window
20mm thick explosion-proof tempered glass and protective steel mesh
- 4
Alarm system
Fault alarm, test end alarm
- Tel
- *Title
- *Content
- Electric Vehicle Recalls and SafetyWith the gradual promotion of new energy vehicles, the number of recalls and complaints is also gradually increasing.
- China Brand DayChinese brand, shared by the world...